Wholesale DC Isolation Transformer for Solar — Factory-Direct OEM/ODM Supply with 15-Day Lead Time
Stop paying a 30–45% distributor markup for a dc isolation transformer. We build 600 V / 1000 V / 1500 V DC isolation transformers for PV arrays, BESS and solar inverters — tested unit by unit, shipped from our own Shenzhen plant to the USA, Europe and English-speaking markets.
For EPC contractors, solar distributors, inverter OEMs and procurement managers who need certified quality, stable landed cost and predictable delivery.
📑 Table of Contents
Why Solar Buyers Lose Money on DC Isolation Transformers
In 2026, PV projects are larger, DC voltages are higher (1500 V is now standard), and procurement teams are under pressure to cut BOM cost without touching safety margins. These are the six problems we hear most often from purchasing managers, technical directors and operations leads.
💸 1. The Middleman Markup
Distributors and trading companies typically add 30–45% on top of ex-works price. On a 200 kVA unit, that is often USD 4,000–7,000 of pure margin you never see.
🔥 2. Low Quality = Field Failures
Cheap windings, thin insulation and skipped partial-discharge testing lead to ground faults, hot spots and inverter shutdowns — a single truck-roll service visit can cost more than the transformer.
🚢 3. Shipping Cost Shock
Transformers are heavy and bulky. LCL freight, ISPM-15 pallet rules and port surcharges can add 18–25% to landed cost if the supplier does not engineer the crate and loading plan.
⏳ 4. Lead Times That Kill Schedules
European and North American stock is often 12–20 weeks out. Every week of delay pushes commissioning and delays milestone payments.
📋 5. Compliance Gaps
Missing UL/CE documentation, no routine test reports, and no IEC 62109-1 alignment means AHJ rejection, re-testing, and delayed interconnection approvals.
🔧 6. Non-Standard Voltages
Real projects need 1000 V DC in, 480 V AC out, or 1500 V DC with 690 V AC — standard catalogue models simply do not fit, and "custom" often means a 6-month engineering cycle.
👉 If two or more of these sound familiar, the next section shows exactly how a factory-direct dc isolation transformer fixes them.
Our Solution: 6 Factory Advantages of the KZD Solar DC Isolation Transformer
Shenzhen Kezhiding Electronic Co., Ltd. (KZD Power) is a physical manufacturer under Taiwan's Kaohsiung Ding Sheng Group. We stamp, weld, wind, insulate, vacuum-dry and test every dc isolation transformer inside our own plant — no trading layer, no outsourced winding, no refurbished cores.
🏭 1. True Source Factory — Zero Middlemen
Brand-new CRGO silicon steel, 99.9% oxygen-free copper and virgin insulation are used in every unit. Because you buy directly from the production line, typical savings of 22–31% versus local distributors are achievable at identical specifications.
🛡️ 2. Galvanic Isolation & Anti-PID Protection
Full galvanic separation between the PV array and the AC side breaks ground loops, blocks common-mode leakage current, and mitigates PID (potential-induced degradation) — recovering 2–5% of module yield on high-voltage strings.
⚙️ 3. Engineered for 1500 V DC Systems
Double-insulated windings, ≥3 kV AC / 1 min routine HV test and ≤10 pC partial discharge ensure long-term dielectric strength on 1000 V and 1500 V strings, with efficiency up to 98.8% on amorphous-core versions.
🎨 4. OEM / ODM Customization
Your logo, your nameplate, your terminal layout, your colour. We support custom kVA ratings, non-standard DC/AC voltages, IP54/IP65 enclosures and customer-branded packaging — with engineering drawings approved within 3 working days.
🧪 5. 100% Routine Testing with Data
Every unit ships with a serial-numbered test report: ratio, no-load loss, load loss, insulation resistance, HV withstand and PD level. Traceability your AHJ, insurer and auditor can actually verify.
🚀 6. High-Speed Delivery & Freight Engineering
Standard models in 15–25 days; optimized crate dimensions, ISPM-15 heat-treated pallets and consolidated LCL/FCL loading plans cut freight volume by up to 17%.
Technical Specifications — Wholesale DC Isolation Transformer for Solar
The table below covers our standard solar dc isolation transformer platform. Anything in the right-hand column can be engineered to your project requirements.
| Parameter | Standard Range | Custom / OEM Option |
|---|---|---|
| Rated power | 5 kVA – 630 kVA | up to 1,200 kVA |
| DC input voltage | 600 / 1000 / 1500 V DC | 200 – 2000 V DC |
| AC output voltage | 220 / 380 / 400 / 415 / 480 V | 110 – 690 V |
| Frequency | 50 / 60 Hz | 50 / 60 / 400 Hz |
| Isolation (HV) test | 3 kV AC / 1 min | 4.5 kV AC / 1 min |
| Insulation class | F (155 °C) | H (180 °C) |
| Efficiency | ≥ 98.2% | ≥ 98.8% (amorphous core) |
| Partial discharge | ≤ 10 pC | ≤ 5 pC |
| Winding material | 99.9% copper, class 155 | copper foil / aluminium |
| Core | CRGO silicon steel | amorphous / nanocrystalline |
| Cooling | AN / ONAN | forced air / water cooled |
| Enclosure protection | IP23 (indoor) | IP54 / IP65 (outdoor) |
| Temperature rise | ≤ 75 K | ≤ 60 K |
| Design standards | IEC 61558-2, EN 61558, IEC 62109-1, UL 1561 | UL 1741, IEEE 1547 alignment |
| Ambient temperature | -25 °C to +45 °C | -40 °C to +55 °C |
| Warranty | 24 months | 36 months (OEM contract) |
📄 Need the full datasheet with loss curves and dimension drawings? Request the 2026 technical pack →
Where Our Solar DC Isolation Transformers Are Used
A dc isolation transformer is not a generic component — its duty cycle, harmonics and thermal profile depend entirely on the application. Here are the four scenarios we build for most often.
☀️ Utility-Scale & C&I PV Plants
Isolation between 1500 V DC strings and central/string inverters; anti-PID duty at night; harmonic decoupling between array and grid.
🔋 Solar + Storage (BESS)
DC-side isolation for battery racks and hybrid inverters, preventing circulating currents between parallel DC buses.
🏠 Off-Grid & Microgrid Systems
Galvanic separation for remote telecom sites, island microgrids and rural electrification where grounding is unreliable.
🏭 Industrial DC Bus & EV Charging
Isolation for solar-fed DC fast-charging hubs and factory DC microgrids feeding CNC and medical equipment.
Field Results from Three Reference Projects
🇺🇸 Texas, 1.2 MW rooftop (2025): Six 200 kVA dc isolation transformers replaced failing third-party units. Measured +4.1% array yield after PID recovery and zero ground-fault trips across 14 months of operation.
🇩🇪 Germany, 1500 V DC EPC package (2025): IP65 outdoor units delivered in 22 days from PO, with full EN 61558 test documentation accepted by the local grid operator at first submission.
🇦🇺 Australia, solar distributor OEM programme (2024–2026): 400+ private-label units per year; landed cost reduced by 31% versus their previous European supplier, with a 0.4% warranty return rate.
💼 Pricing, Payment & Compliance — What You Need to Know
💰 Pricing Method
Quoted FOB Shenzhen as standard
CIF / CFR to your nearest port available
DDP door delivery for EU/US/UK (duty & VAT handled)
Volume tiers: 1–4 units / 5–19 units / 20+ units
Price valid 30 days; copper-index clause available on 12-month contracts
💳 Payment Terms
30% T/T deposit, 70% before shipment
L/C at sight accepted for orders above USD 50,000
PayPal / Alibaba Trade Assurance for sample orders
Net 30 available after three completed orders
All prices exclusive of local import duty and VAT
📜 Regulatory Compliance
CE marking with EU Declaration of Conformity
UL / cUL recognised component options for US & Canada
RoHS & REACH material declarations
ISO 9001:2015 quality management system
Installation must follow local code — NEC Article 690 (US), HD 60364 / IEC 60364 (EU)
⚠️ Note: Product descriptions, ratings and compliance documents are provided for engineering reference. Final selection, grounding design and installation must be validated by a licensed local engineer in your jurisdiction.

Factory Proof, Certificates & Customers
We know that a factory claim means nothing without evidence. Here is a look inside our Shenzhen production base — winding, vacuum drying, assembly and final test.
Certifications

Trusted By Engineering Teams Worldwide

What Buyers Say (with numbers)
"We replaced two European-sourced units with KZD's 150 kVA model. Landed cost dropped 26% and the test reports were more complete than what we had before."
— Procurement Manager, EPC contractor, Netherlands
"Their engineers reviewed our single-line diagram and corrected the grounding arrangement before production. That saved us a 3-week redesign."
— Technical Director, solar integrator, Texas
"22 days from PO to port, three shipments in a row. Our warehouse downtime fell to near zero."
— Supply Chain Manager, distributor, UK
FAQ — Wholesale DC Isolation Transformer for Solar
1. What is a dc isolation transformer used for in a solar system?
It provides galvanic isolation between the PV array (DC side) and the inverter or AC distribution side. This breaks ground loops, limits common-mode leakage current, mitigates PID, and decouples harmonics — improving safety and long-term module performance.
2. What is your minimum order quantity (MOQ) for wholesale orders?
MOQ is 1 unit for standard models so you can evaluate quality first. Volume pricing starts at 5 units, and OEM/private-label programmes typically begin at 10 units per rating.
3. Can you customize voltage, kVA rating and enclosure for our project?
Yes. Non-standard DC input (e.g. 1200 V DC), custom AC output, IP54/IP65 enclosures, special terminal layouts and your own nameplate are all supported. Drawings are issued for your approval within 3 working days.
4. What certifications come with the transformer?
Standard supply includes CE Declaration of Conformity, RoHS declaration and an ISO 9001 quality certificate. UL/cUL recognised component versions are available on request for the US and Canadian markets.
5. How long is production and delivery?
Standard models ship in 15–25 days after deposit. Custom units take 25–35 days. Sea freight to US West Coast is typically 18–25 days; to Europe 28–35 days. Air and rail options are quoted on request.
6. How do you control shipping costs for heavy equipment?
We engineer the crate dimensions, use ISPM-15 heat-treated pallets, and provide a loading plan that maximises container utilisation. On multi-unit orders this typically reduces freight volume by 12–17% versus unoptimised packing.
7. Do you provide test reports and documentation for each unit?
Yes — every unit is serial-numbered and shipped with a routine test report covering ratio, no-load loss, load loss, insulation resistance, HV withstand and partial discharge. Nameplate, wiring diagram and installation manual are included.
8. What after-sales support is included?
24-month standard warranty (36 months for OEM contracts), 24-hour response by phone or email, remote technical diagnosis with our engineering team, and spare-part availability for 10 years after delivery.
Get Your Factory-Direct Quote in 24 Hours
Send us your DC voltage, kVA rating and destination port. You will receive a priced quotation, a dimension drawing and a freight estimate — usually within one business day.
⏳ Q1 2026 production slots are limited — 6 allocation windows remaining this month.
Verified Customer Reviews
Real feedback from buyers who placed and received orders between 2024 and 2026.

Mark R.
Procurement Manager · Solar EPC · Arizona, USA
★★★★★
"We ordered four 250 kVA dc isolation transformers for a 1.2 MW site. Documentation was complete, the test reports matched the nameplates, and the units passed inspection without a single remark. Lead time was 19 days."

Sandra K.
Technical Director · Integrator · Munich, Germany
★★★★★
"I asked very specific questions about partial discharge values and winding insulation. Their engineer answered with actual test data, not marketing text. PD measured at 6 pC on our units."

David L.
Operations Manager · Distributor · Manchester, UK
★★★★★
"Third order in 14 months. Consistent quality, consistent packing, consistent communication. Warranty returns under 0.5% across roughly 180 units — that is better than our previous two suppliers combined."

Priya N.
Supply Chain Manager · Off-grid Systems · Melbourne, Australia
★★★★★
"The OEM programme was the deciding factor. Our logo, our nameplate, our packaging — delivered exactly as approved. Freight cost per unit dropped 17% after they reworked the crate layout."
Real Conversations with Overseas Buyers
Screenshots of actual WhatsApp and email exchanges (names partially redacted for privacy).












